Prominent & Leading Manufacturer from Ghaziabad, we offer delta inverter vfd, l&t hx 2000 ac drives, l&t ex2000 series ac drives, l&t fx2000 ac drives, l&t cx2000 ac drive and variable frequency drive inverter.
₹ 9500 / Piece Get Latest Price
| Phase | Three phase |
| Power | 3 HP |
| Usage | for Industrial Machinery |
| Brand | Delta |
| Model Name/Number | VFD |
| Input Voltage | 460V |
| Input Phase | 3 - Phase |
Minimum order quantity: 1 Piece
₹ 10000 / Unit Get Latest Price
| Overload Capacity | HD : 150%/ 1Min; ND: 110%/ 1Min |
| Motor Rating | 0.1 kW |
| Applicable Motor (HD) | 0.12-10 |
| Applicable Motor (ND) | 0.25-15 |
| Rated Capacity(KVA) | 0.3-12.2 |
| Rated Current | 0.8-32.0 |
| Max. Output Frequency | 400 [Hz]3 |
| Max. Output Voltage | Three-Phase 200 ~ 240V4 |
| Rated Voltage [V] | Three Phase 200 ~ 240 VAC (-15% ~ +10%) |
| Input Ratings(HD) | 0.7-28.6 |
| Rated Frequency | 50 ~ 60 [Hz] (5%) |
| Cooling Type | Natural Cooling And Forced Cooling |
| Control Type | V/F Control, Sensorless Vector Control, Slip Compensation |
| Frequency Precision Setting | Digital Command: 0.01Hz Analog Command: 0.05Hz (Max. Frequency: 50Hz |
| V/F Pattern | Linear, Squared, User V/F |
| Torque Compensation | Manual/Auto Torque Compensation |
| Max. Brake Torque | 20% |
| Time/%ED | 150%2) When Using Optional DB Resistor |
| Operation Mode | Keypad / Terminal / Communication operation |
| Operational Functions | PID Control, Up-Down Operation, 3-Wiring Operation, Draw Mode |
| Analog Input | Signal Input: 0-10V, 0-20mA (programmable) |
| Protection Degree | Opening (IP 20) |
| Storage Temperature | -20 DegreeC ~ 65 Degree C |
| Relative Humidity | Below Relative Humidity 90% RH (No Condensation) |
| Altitude/Vibration | Below 1000m, 5.9/sec(0.6G) |
| Atmospheric Pressure | 70~106 kPa |
| Installation Environmen | No Corrosive Air, Combustible Gas, Oil Mist, Etc. |
₹ 7000 / Unit Get Latest Price
| Analog Input (Voltage + Current)/Output | (1+1) points /4 points |
| Motor Rating(KW) | 12 KW |
| Voltage | 380~480V |
| Digital Input/Output | 8 points / 5 points |
| External Option | Built-in |
| Drive Capacity(KW) | 315 ~ 375(KW) |
| Grounding Wire Sizes, KCMIL (mm) | 400 (200) |
| Kgf CM | 7.1~12.2, 182.4~122.6 |
| Forward Run | Forward Run When Closed And Stopped When Open |
| Reverse Run | Reverse run when closed and stopped when open |
| Fault Reset | Used For Fault Reset |
| Sequence Common | Common Terminal For NPN Contact |
| Analog Power Source | Power Supply For Analog Frequency Setting. Maximum Output : +12V, 100mA, -12V, 100mA |
| External MotorThermal Detection | NT (~30kW) |
| Built-In RS485 Termina | C+, C- |
| Analog Output | S0, S1 |
| Contact | A1~4, C1~4 Digital |
₹ 7500 / Unit Get Latest Price
| Overload Capacity | HD : 150% for 1min; ND: 110% for 1min |
| Digital Input | 8 (Programmable NPN/PNP) |
| Digital Output | 4 (R) (Programmable NO/NC) + 1 (TR) |
| Analog Input | 1 (4 to 20mA) & 1 (0 to 10Vdc) |
| Analog Output | 2 (0 to 10Vdc) |
| Pulse Input | 1 Input (0 to 30kHz) |
| Pulse Output | 1 Output (0 to 30kHz) |
| NTC/PTC Input | 1 |
| Max Input Voltage | Three-Phase 380 ~ 480 VAC (-15% ~ +10%) |
| Rated Frequency | 50/60Hz (-5/+5%) |
| Max Output Voltage | Proportional to Input Voltage |
| Max Output Frequency | 0 to 120Hz |
| Keypad | Detachable LCD |
| DC Reactor | Built-in 22 to 280kW (ND) |
| Features | DC Braking,Reverse Rotation Prevention,Auto Restart,Inverter By-Pass,Auto-Tuning,PID Control. |
| Control Method | V/F,Sensorless Vector,Slip Compensation,Easy Start Selectable |
| Frequency Precision Setting | Digital Reference: 0.01 Hz (Below 100 Hz),0.1 Hz (Over 100 Hz)Analog Reference: 0.01 Hz / 60 Hz |
| Frequency Control Range | 0.01 to 120Hz |
| Output Frequency Resolution | 0.01Hz below 100Hz,0.1Hz over 100Hz |
| V/F Pattern | Linear,squared,user V/F |
| Starting Torque | 200% at 0.5Hz for Sensorless Control |
| Accel/Decel Time | 0.0 to 6000 Sec |
| Faults | Over Voltage,Low Voltage,Over Current,Ground Fault,Inverter Overheat,Motor Overheat. |
| Alarm | Stall Prevention,Overload Alarm,Thermal Sensor Fault |
| Trip Information | Max. 5 Faults are saved |
| Protection Degree | IP20 till 11kW & IP00 till 450kW |
| Ambient Temperature | HD operation: - 10 ~ 50 DegreeC (no freezing) |
| Storage Temperature | -20 DegreeC ~ 65 Degree C |
| PCB Protection | Conformal Coating Complying to IEC 60721-3-3 class 3C2 |
| Relative Humidity | Below relative humidity 90% RH (no condensation) |
| Altitude/Vibration | Below 1000m,5.9m/sec2 (0.6G) |
| Atmospheric Pressure | 70~106 kPa |
| Installation Environment | Pollution degree 2,No Corrosive Gas,Combustible Gas,Oil Mist,or Dust |
| Global Compliance | CE,UL,RoHS |
₹ 6000 / Unit Get Latest Price
| Overload Capacity | HD : 150% for 1Min; ND: 110% for 1Min |
| Motor Rating | 0.1 kW |
| Applicable Motor (HP) | 1/8-3 |
| Applicable Motor (HD) | 0.3-4.2 |
| Max. Output Frequency | 400 [Hz]3 |
| Rated Voltage [V] | Single-Phase 200 ~ 240 VAC (-15% ~ +10%) |
| Input Ratings | 1.4-24 |
| Cooling Type | Natural Cooling And Forced Cooling |
| Rated Current | 0.8-11 |
| Max Input Voltage | Single-Phase 200 ~ 240 VAC (-15% ~ +10%)Three-Phase 380 ~ 480 VAC (-15% ~ +10%) |
| Keypad | LED (Non detachable) |
| Braking Chopper | Built-In |
| Control Method | V/F Control, Sensorless Vector Control, Slip Compensation |
| Frequency Precision Setting | Digital command: 0.01Hz Analog command: 0.03Hz (Max. frequency: 50Hz) |
| Frequency Control Range | 0.01 to 400Hz for V/F , 0 to 120Hz for Sensorless Vector Control |
| Output Frequency Resolution | 0.01Hz |
| V/F Pattern | Linear, Squared, User V/F |
| Starting Torque | 150% at 3 Hz in V/F |
| Accel/Decel Time | 0.0 to 6000 Sec |
| Torque Compensation | Manual/Auto Torque Compensation |
| Operation Mode | Keypad / Terminal / Communication Operation |
| Operational Functions | PID Control, Up-Down Operation, 3-Wiring Operation, Draw Mode |
| Alarm | Stall Prevention, Overload |
| Momentary Power Loss | Below 16 msec: Continuous Operation Above 16 msec: Auto Restarting. |
| Protection Degree | Opening (IP20) |
| Storage Temperature | -20 DegreeC ~ 65 DegreeC |
| PCB Protection | Conformal Coating Complying To IEC 60721-3-3 Class 3C2 |
| Relative Humidity | Below Relative Humidity 90% RH (No Condensation) |
| Altitude/Vibration | Below 1000m, 5.9m/sec2 (0.6G) |
| Atmospheric Pressure | 70~106 kPa |
| Installation Environment | No Corrosive Air, Combustible Gas, Oil Mist, Etc. |
| Global Compliance | CE, UL, RoHS |
₹ 9800 / Piece Get Latest Price
| Usage | for Industrial Machinery |
| Brand | Delta |
| Input Phase | 3 Phase |
| Product specific application | Any |
| Country of Origin | Made in India |
₹ 12500 / Piece Get Latest Price
| Power | 5 HP |
| Usage | for Industrial Machinery |
| Brand | INVT |
| Model Name/Number | GD200/GD100/GD20 |
| Input Voltage | 200V- 440V AC |
| Input Phase | 3 - Phase |
₹ 9500 / Unit Get Latest Price
| Overload Capacity | HD: 150% for 1 Minute, ND: 120% For 1 Minute |
| Motor Rating(Normal Duty) | 0.75 kW-90 kW |
| HeavyDuty(HP) | 0.5-3.0 |
| Capacity Heavy Duty [HD] | 1.0-4.2 |
| Rated Current | 2.5-11.0 |
| Frequency [Hz] | 0~400Hz (IM Sensorless : 0~120[Hz]) |
| Voltage [V] | 3-phase 200~240V |
| DC Reactor | External [option] |
| Display | LED [LCD optional] |
| Braking Unit | Built-in |
| Keypad | Built-In LED Till 30 kW(ND) & Above 30kW Standard Detachable LCD |
| Braking Chopper | Built-In Upto 30 kW(ND) |
| Features | Multi Keypad, Peer to Peer Communication to share I/O's, User Sequence, Inbuilt PID |
| Control Method | V/f, Slip Compensation, Sensorless Vector Contro |
| Frequency Setting Resolution | Digital command: 0.01Hz / Analog Command: 0.05Hz (Maximum Frequency: 50Hz) |
| Output Frequency Resolution | 0.01Hz |
| V/F Pattern | Linear, Squared, User V/F |
| Torque Boost | Manual/Automatic Torque Boost |
| Starting Torque | 200% At 0.5Hz For Sensorless Control & 150% At 3 Hz For V/F |
| Accel/Decel Time | 0.0 to 6000 Sec |
| Braking Torque | Continuous Regeneration Torque 20% (150% With DBR) |
| Operation Mode | Keypad / Terminal / Communication Option Selectable |
| Analog Input | V1:- 10~10V, V2:- 0~10V/4~20mA Selectable |
| Pulse Train | 0Hz~32kHz, Low level: 0~0.8V, High level: 3.5~12V |
| Analog Output | 1 (4-20mA / 0 to 10Vdc) till 22kW & 1 (4-20mA) + 1 (0 to 10Vdc) above 22kW |
| Safety I/P | 2 |
| Communication | Built-in RS485 Modbus RTU.Optional: CANopen, Profibus DP, Modbus TCP, Ethernet I/P |
| Forced Cooling Type | 0.8-15 kW 230V/1.5-75 kW 415V |
| Protection Degree | IP20/UL Open (Default), UL Enclosed Type 1 (Option), IP66/NEMA 4X (Option) |
| PCB Protection | Conformal Coating Complying to IEC 60721-3-3 Class 3C2 |
| Storage Temperature | -20 ~ 65 degrees C |
| Humidity | Relative Humidity Below 90% RH (No Dew Formation) |
| Altitude, Vibration | Below 1,000m, below 5.9m/sec2 (0.6G) |
| Location | No Corrosive Gas, Flammable Gas, Oil Mist Etc. Indoors (Pollution Degree 2 Environment) |
Mr. Ravi Kumar (Proprietor)
Unicorn Automation India
Khasra no. 337 Village Asalat Nagar
Ghaziabad - 201206, Uttar Pradesh, India